ICDM Updates can be found at this site

The IDMS1 was officially released June 1, 2012. This site is the home for updates to the IDMS and related items.

The Errata listed here are changes to sections of the IDMS to correct errors which were found on a per-section basis by users of the document. They were reviewed internally, and then the ICDM membership was given access to the errata before they were posted here, to help verify their accuracy and to help assure no one had any issues or concerns about them.


IDMS Errata Revision Record and Update Access

Listing: IDMS Errata Revision History
Release IDMS Vers. Ch. Chapter Section Section Title Rev Date Approver Description of Change
IDMS1 1.03

11

Reflection 11.7.3.1

Removal of Lambertian Component from Specular Result

01 11/1/12 John Penczek Correction of Eq. (1) to account for the distance of the source from the display. Addition of Comments explaining the calculation.
IDMS 1.03 8 Uniformity 8.2.3 Mura Analysis 01 2/16/13 Andrew Watson

-1- Equation (1) was missing a minus sign in front of the π ; a minus sign has been added.
-2- Equation (5) was duplicated on the same line; duplicate removed.

  "   " "   "   " Mura Analysis 02 5/3/13 Andrew Watson

Eq. (6): pxpy is replaced with r -2: pxpy are horizontal and vertical pixel widths in degrees, but we have assumed square pixels with r being the number of degrees per pixel.

  "   " "   "   " Mura Analysis 03 5/31/13 Andrew Watson

Eq. (6): r -2 is replaced with (k/r)2 as in Eq. (5).

IDMS 1.03 8 Uniformity 8.0 Introduction section, Color uniformity 01 3/25/13 Ed Kelley Equation (3) was in error. Changed v'1+v'2 to v'1-v'2
IDMS 1.03 5 Fundamental 5.31 Volume-Color-Reproduction Capability 01 3/26/13 Jongho Chong -1- Added numbers to the equations in the section.
-2- For the measurement analysis for Equation (8), the gradation equation for LQn is changed to include LQmin (measured black luminance) in place of "0" for black, and the definition of LQmin is explained. LQmin is added as an offset to assure the equation never goes to 0 for any of the values of n.
-3- Fixed typo in name of Fig. 2, to make it “Triangulations.”
-4- Fixed minor typos in the Application paragraph.
IDMS 1.03 10 Temporal 10.1 Warm-up Time 01 4/21/13 Ed Kelley

-1- Changed Procedure paragraph:
...; the time of the beginning of the measurement is ti.
    to be
...; the time of the beginning of the measurement is t1, and ti represents the times for the remaining Li measurements.
-2- Changed Analysis paragraph:
... ∂L = 0.01L (1% of the average).
    to be
....∂L = 0.05L (5% of the average).

IDMS 1.03 17 3D & Stereoscopic Displays 17.2.7 Stereoscopic Gray-to-Gray Average Crosstalk 01 4/26/13 Adi Abileah

-1- Eq. (2) last two indices should have been "jj".
-2- Table 1 percent signs removed, units added, significant figures made consistent.

IDMS 1.03 3 Setup of Display & Apparatus 3.6 Coordinate Systems & Viewing Angles 01 10/10/14 Ed Kelley

Was
   -a- Column 2: North Polar (Independent Axis Vertical)
   -b- Column 3: East Polar (Independent Axis Horizontal)


Changed to be
   -a- Column 2: North Polar (Independent Axis Horizontal)
   -b- Column 3: East Polar (Independent Axis Vertical)

Release IDMS Vers. Ch. Chapter Section Section Title Rev Date Approver Description of Change

IDMS Errata Document Access

Download the link via the Errata Document Title.

Section Title

Download here by
Errata Documents Titles

11.7.3.1 Removal of Lambertian Component from Specular Result 11p7p3p1-01-20121101.pdf
8.2.3 Mura Analysis 8p2p3-03-20130531.pdf
8.0 Introduction section, Color uniformity 8p0-01-20130325.pdf
5.31 Volume-Color-Reproduction Capability 5p31-01-20130326.pdf
10.1 Warm-up Time 10p1-01-20130421.pdf
17.2.7 Stereoscopic Gray-to-Gray Average Crosstalk 17p2p7-01-20130426.pdf
3.6 Coordinate Systems & Viewing Angles 3p6-01-20140905.pdf

 

 

 


 

Latest document release: The IDMS1 Version 1.03, June 1, 2012

 

 

 